CIP, or cleaning in place, is a system for cleaning process installations without dismantling them. In practice, this means that tanks, pipelines, heat exchangers, pumps, valves, filling lines or other process components are cleaned by circulating appropriately selected cleaning, rinsing, and disinfecting solutions. Instead of dismantling the installation, the plant runs a programmed cleaning sequence, controlling the time, temperature, flow, chemical concentration, and rinsing quality.
CIP cleaning is widely used in the food, dairy, beverage, brewing, cosmetics, pharmaceutical, and chemical industries, and anywhere that installations are enclosed and require consistent hygiene. In a well-designed CIP system, downtime can be reduced, labor reduced, personnel safety improved, and a consistent level of cleanliness achieved. However, this requires the correct selection of chemicals, process parameters, and control procedures.
CIP is not a single chemical or a simple rinsing of the installation with water. It is a technological process in which the following are important: the type of soiling, the design of the installation, turbulent flow, temperature, working solution concentration, contact time, water quality, the sequence of stages, material compatibility and the method of confirming cleaning effectiveness.
The shortest recommendation
In most plants, the CIP process should be treated as a controlled procedure, not as "rinsing the installation with chemicals". Alkaline cleaning mainly removes fats, proteins, and organic soiling. Acid cleaning removes scale, mineral deposits, and inorganic deposits. Rinsing removes chemical and soiling residues. Disinfection or sanitization is a separate stage that should be carried out exclusively with a product intended for that specific application, in accordance with the label and legal requirements. The most common mistake is selecting chemicals without analyzing the soiling, installation materials, and flow parameters.
1. What does CIP mean?
CIP is an abbreviation of the English cleaning in place, meaning cleaning in place without dismantling the installation. Unlike COP, or cleaning out of place, where components are dismantled and cleaned separately, CIP uses the circulation of cleaning solutions through the existing installation. The solution circulates through the tank, pipelines, pumps, valves, heat exchangers, cleaning balls, nozzles, or rotary heads.
A well-executed CIP should remove product residues, deposits, biofilm, fats, proteins, carbohydrates, scale, or other contaminants from the internal surfaces of the installation. In many plants, CIP is part of the hygiene, quality, and product safety program. However, simply starting the circulation does not guarantee effectiveness. What matters is whether the solution actually reaches all surfaces and works with the appropriate energy, temperature, and contact time.
| Concept | Practical meaning | Examples |
|---|---|---|
| CIP | Cleaning the installation without dismantling | Tanks, pipelines, heat exchangers, filling lines |
| COP | Cleaning components after dismantling them from the installation | Filters, small parts, seals, nozzles, valve components |
| SIP | Sterilization or sanitization in place, depending on the industry and procedure | Steam, hot water, chemicals in specific processes |
| Working solution | Chemical diluted to the concentration used in the process | Alkaline, acid, disinfecting, or rinsing solution |
| Validation and verification | Confirming that the cleaning process works and continues to work in practice | Microbiological tests, ATP, conductivity, pH, inspection, rinse samples |
2. Where is CIP cleaning used?
CIP is used primarily where dismantling the installation would be time-consuming, costly, or increase the risk of contamination. This applies to plants operating in a repetitive manner, with a large number of production cycles, where the installation must be cleaned between batches, at the end of a shift, after a product change, or after a specified operating time.
Typical industries and areas of application
- dairy industry - tanks, pasteurizers, pipelines, yogurt and whey lines,
- beverage industry - juice, syrup, and beverage lines, tanks, and filling installations,
- breweries and wineries - tanks, fermenters, transfer lines, heat exchangers,
- food industry - sauces, preserves, ready-to-eat liquid and semi-liquid products,
- cosmetics and household chemicals - tanks, mixers, dispensing lines,
- pharmaceuticals and biotechnology - systems requiring high repeatability and documentation,
- technical plants - dispensing installations, process tanks, and auxiliary systems.
In each of these industries, the CIP process may look different. Different types of soiling occur in dairies, breweries, cosmetics, and with fatty or sugary products. Therefore, a CIP program should not be copied from one plant to another without validation and assessment of local conditions.
3. How does effective CIP cleaning work?
The effectiveness of CIP depends on several factors acting simultaneously. In classic cleaning theory, people often speak of Sinner's circle: chemicals, time, temperature, and mechanical action. In CIP, mechanical action means primarily flow, turbulence, and the energy of the stream reaching the surface. If one of these parameters is too weak, the others must partially compensate, but this is not always possible.
| Factor | Importance in CIP | Example mistake |
|---|---|---|
| Chemicals | Selecting alkalies, acids, oxidizing agents, surfactants, or disinfectants for the soiling | Using a single product for all deposits |
| Time | The solution must act long enough to dissolve or remove the soiling | Shortening the program without confirming effectiveness |
| Temperature | Affects reaction speed, soiling solubility, and chemical effectiveness | Operating at too low a temperature or overheating a sensitive product |
| Flow and turbulence | Responsible for mechanically removing soiling and reaching the surfaces | Too low flow, dead zones, poorly selected nozzles, or cleaning balls |
| Water | Water quality affects foaming, mineral deposits, rinsing, and chemical effectiveness | Ignoring water hardness and rinsing residues |
A professional CIP program should specify not only the name of the chemical, but also its concentration, temperature, circulation time, flow, solution volume, rinsing method, and criteria for completing the stage. Otherwise, the process is difficult to control and repeat.
4. Typical CIP process sequence
There is no single universal CIP program for all installations, but in practice, several basic stages are encountered. Depending on the industry, soiling, and required hygiene, the process may be shorter or more extensive.
Stage 1: pre-rinsing
Pre-rinsing is intended to remove loose product residues, sugars, milk residues, syrup, fat, foam, deposits, or suspensions. This stage reduces chemical consumption in the next step and reduces the risk of neutralizing the cleaning solution with contaminants. In many processes, water temperature is important: if too cold, it may poorly remove fats, and if too hot, it may fix some proteins on the surface.
Stage 2: alkaline cleaning
Alkaline cleaning is usually the basic stage for removing organic soiling. Alkaline solutions help remove fats, proteins, carbohydrates, process deposits, and some biofilm. Depending on the process, sodium hydroxide, potassium hydroxide, alkaline mixtures, products with sequestrants, surfactants, corrosion inhibitors, or defoamers are used.
Stage 3: post-alkaline cleaning rinsing
After the alkaline stage, residues of alkalies and detached soiling must be removed. Rinsing control can be carried out by measuring conductivity, pH, rinsing time, or a specified volume of water. Too short rinsing causes a risk of carrying chemical residues into the next stage or into production.
Stage 4: acid cleaning
Acid cleaning removes mineral deposits, milk stone, calcium, magnesium, iron, and other inorganic deposits. Depending on the installation, phosphoric, nitric, citric, lactic acid, or acid mixtures with auxiliary additives are used. The acid stage is particularly important where hard water, temperature, and product composition favor the formation of mineral deposits.
Stage 5: final rinsing
Final rinsing removes residues of the acid solution and prepares the installation for the next step: production, disinfection, sanitization, or drying. In many plants, final rinsing is controlled by conductivity, pH, or other water quality parameters. If the installation comes into contact with food, cosmetics or a product requiring microbiological cleanliness, the rinsing stage is critical.
Stage 6: disinfection or sanitization
Disinfection or sanitization should not be treated as a substitute for cleaning. If the surface is not cleaned, organic residues may reduce the effectiveness of the disinfectant. Depending on the industry and requirements, products based on different active substances are used, such as peracetic acid, hydrogen peroxide, sodium hypochlorite, or other approved formulations. A product with declared biocidal action must be used in accordance with its intended purpose, label, and legal requirements.
5. What chemicals are used in CIP?
CIP chemical selection should be based on the type of soiling, installation materials, water quality, temperature, hygiene requirements, and the desired effect. A different approach is required for an installation after a dairy product, after sugar syrup, after a fatty product, and after a cosmetic or chemical formulation.
Alkaline products
Alkaline products are the basis of many CIP programs. Their task is to remove organic soiling: fats, proteins, process deposits, product residues, soiling of plant and animal origin. Solutions based on sodium hydroxide or potassium hydroxide are most commonly used, often with additives that sequester, disperse, defoam, and aid rinsing.
Strongly alkaline products can be corrosive and require proper worker protection. Not every installation material tolerates high pH, temperature, and long contact time well. Particular care should be taken with aluminum, light metals, certain seals, elastomers, and coated surfaces.
Acid products
Acid products are used primarily to remove mineral deposits. In CIP, they are used where scale, milk stone, calcium, magnesium, iron, or other inorganic deposits form. Acid preparations may be based on phosphoric, nitric, citric, or lactic acid, or acid mixtures with technological additives.
Acid products should not be mixed with sodium hypochlorite or other chlorine products, because chlorine may be released. It should also not be assumed that acid CIP is suitable for every installation. Material resistance must be assessed, including steel, welds, seals, sensors, pumps, and fittings.
Defoaming products
Many CIP systems require defoaming products. Excessive foam can disrupt the operation of pumps, sensors, flow meters, cleaning balls, level systems, and conductivity sensors. A product that works well in manual foam cleaning may be unsuitable for CIP if it foams too intensely.
Sequestering and chelating products
Hard water and metal ions can reduce cleaning effectiveness and promote deposits. Therefore, CIP formulations use ingredients that bind calcium, magnesium, and metals, improving solution stability and reducing deposit formation. The selection of such additives depends on water quality and the type of soiling.
Oxidizing products
In some programs, oxidizing products are used, such as hydrogen peroxide, peracetic acid, sodium hypochlorite, or other formulations. Their task may be to support hygiene, break down selected organic compounds, reduce odors, or perform a sanitization stage. Oxidizing products require special control, as they may react with incompatible materials, organic substances, reducing agents, and metals.
Enzymatic products
In selected applications, enzymatic products can be used, especially when soiling has a specific organic character, such as protein, starch, or fat. Enzymes work within a specific pH and temperature range, so they require precise process conditions. Too high a temperature or incorrect pH may reduce their effectiveness.
Disinfectant and sanitizing products
Products used for disinfecting installations must be selected for the required range of action, surface, industry, and regulations. If a product has declared biocidal action, it is subject to requirements for biocidal products. In practice, it must be checked whether the product is intended for the given area, such as surfaces in contact with food, process installations, process water, or a specific type of surface.
| CIP product group | Main application | What to watch out for? |
|---|---|---|
| Alkaline | Fats, proteins, organic residues, process deposits | Corrosive action, aluminium, seals, high pH, temperature |
| Acidic | Scale, mineral deposits, milk stone, calcium and magnesium deposits | Do not mix with chlorine; check the resistance of steel, seals and sensors |
| Low-foaming | Circulating processes, pumps, pipelines, automatic systems | Excessive foam can disrupt flow and measurement |
| Sequestering | Hard water, mineral deposits, stabilization of the washing solution | Selection depends on water quality and temperature |
| Oxidising | Hygiene, odour reduction, sanitisation, selected technological processes | Reactivity, incompatible materials, risk of decomposition or corrosion |
| Enzymatic | Selected organic soiling, biofilm, specialised processes | Sensitivity to pH and temperature |
| Biocidal/disinfectant | Microorganism reduction after the washing stage | Proper purpose, contact time and regulatory compliance required |
6. Washing and disinfection - why are they not the same?
One of the most common mistakes in practice is treating disinfection as a substitute for washing. Washing removes soiling, deposits, product residues and some microorganisms through chemical and mechanical action and rinsing. Disinfection is intended to reduce the number of microorganisms to the required level, but its effectiveness can be significantly lower if the surface is dirty.
In CIP, the disinfection stage should follow effective washing and rinsing, unless a specific procedure has been designed and validated otherwise. The disinfectant should come into contact with a clean surface for the required time and at the correct concentration. Residues of alkalis, acids or soiling can reduce its effectiveness or cause unwanted reactions.
7. Parameters that need to be controlled
The CIP system should be controlled by parameters that can be measured and documented. Without this, it is difficult to prove that the process is repeatable. In practice, the most commonly controlled parameters are temperature, time, chemical concentration, conductivity, pH, flow, pressure, rinse volume, tank levels and rinse end criteria.
| Parameter | Why is it important? | How can it be controlled? |
|---|---|---|
| Chemical concentration | If too low, it may not wash; if too high, it increases the risk of corrosion and cost | Conductivity, titration, automatic dosing |
| Temperature | Affects fat dissolution, chemical reactions and washing effectiveness | Temperature sensors, cycle recording |
| Contact time | The solution must act for a sufficient amount of time | Controller program, cycle time recording |
| Flow | Responsible for turbulence and mechanical removal of soiling | Flow meters, pressure, pump control |
| pH | Helps confirm the nature of the solution and rinsing effectiveness | Manual or automatic measurements |
| Conductivity | Facilitates the detection of chemicals in the circuit or rinse | Conductivity probes, limit values |
| Water quality | Hardness and impurities affect deposits and chemical effectiveness | Water testing, hardness control, treatment |
8. CIP validation, monitoring and verification
In a professional facility, it is not enough to state that the CIP program has been run. It must be confirmed that the program removes soiling and maintains the required level of hygiene. For this purpose, validation, monitoring and verification are used.
Validation
Validation answers the question: is the designed CIP process capable of effective washing under specified conditions? It includes tests in a real installation, assessment of the most difficult areas, soiling analysis, rinse testing, microbiological tests, ATP, protein, conductivity, pH or other industry-specific indicators.
Monitoring
Monitoring answers the question: has every cycle been performed according to the established parameters? In practice, this means recording temperature, time, flow, concentration, conductivity and the sequence of stages. If the cycle deviates from the parameters, the system should detect this, and personnel should know what to do.
Verification
Verification answers the question: does the process still deliver the expected result in daily operation? It may include periodic microbiological testing, inspections, ATP testing, trend analysis, complaint assessment, chemical residue control, documentation review and hygiene audits.
9. Installation design matters
Even the best chemical will not clean an installation that is poorly designed. In CIP systems, dead legs, improper slopes, air pockets, poorly selected valves, incorrect seals, too small diameters, lack of drainage, poorly positioned spray balls and areas where the solution does not reach with sufficient speed are particularly problematic.
In practice, this means that CIP problems are not always solved by stronger chemicals. Sometimes the cause is the installation design, too low flow, a clogged nozzle, a worn cleaning ball, a dead zone behind a valve or too short a contact time. Therefore, when problems recur, the entire system must be analysed, not just the chemical concentration changed.
10. Safety when working with CIP chemicals
CIP chemicals often have high or low pH, corrosive or oxidising properties, or are hazardous to the environment. Therefore, every product should have an up-to-date Safety Data Sheet (SDS), CLP label and instructions for use. The SDS sections on hazard identification, personal protective equipment, storage, stability, reactivity and spill procedures are particularly important.
Basic health and safety principles
- do not mix alkaline, acidic, chlorine and oxidising chemicals except as approved by a procedure,
- do not pour chemicals into unmarked containers,
- use gloves, goggles, face protection and protective clothing in accordance with the SDS,
- ensure ventilation in the area where solutions are prepared,
- check the compatibility of chemicals with pumps, seals, hoses and tanks,
- secure the storage area against spills and accidental mixing of products,
- train staff in diluting, connecting, disconnecting and emergency shutdown of the system,
- do not shorten the CIP program without confirming the effectiveness of the process.
11. Most common CIP mistakes
Mistake 1: treating CIP like regular rinsing
Water flow through the installation alone does not remove all soiling. Fats, proteins, mineral deposits and biofilm require appropriately selected chemicals, temperature, time and turbulence.
Mistake 2: using one chemical for everything
Alkaline and acidic chemicals have different purposes. A product for fat does not have to remove scale, and a descaler does not replace alkaline washing. Many installations require at least two washing approaches: alkaline and acidic.
Mistake 3: too low flow
CIP requires sufficient mechanical energy. Too low flow can cause a lack of turbulence, poor removal of soiling and incomplete cleaning of pipelines. In tanks, the problem may be poorly selected spray balls or too low pressure.
Mistake 4: lack of concentration control
Diluting by eye leads to inconsistent results. A solution that is too weak will not remove soiling, while one that is too strong increases cost, corrosion risk and wastewater load. Concentration should be controlled by conductivity, titration or another method appropriate for the product.
Mistake 5: incorrect temperature
Temperature affects washing effectiveness, but it is not always true that “the warmer, the better”. A temperature that is too low may not remove fat, while one that is too high can set certain types of soiling, increase corrosion or reduce the stability of selected chemicals.
Mistake 6: skipping rinsing between stages
Rinsing between alkaline and acidic chemicals reduces the risk of neutralisation, uncontrolled reactions and the carryover of chemical residues. Skipping rinsing can disrupt the next stage of the process.
Mistake 7: disinfecting a dirty installation
A disinfectant does not replace effective washing. Organic residues can reduce its effectiveness. Soiling must be removed first, and only then should the disinfection or sanitisation stage be carried out.
Mistake 8: lack of validation after changing the product or formulation
Changing the washing product, production formulation, raw material supplier, temperature, time or installation design can change CIP effectiveness. After significant changes, it must be assessed whether the procedure still works.
12. Checklist for the purchasing department
- Is the product intended for CIP, rather than just manual or foam washing?
- Is the chemical low-foaming and suitable for a closed circuit?
- Is it known what soiling it is intended to remove: fat, protein, sugar, scale, mineral deposits, biofilm?
- Is the recommended working concentration and operating temperature known?
- Is the product compatible with the installation materials: steel, seals, pumps, valves and sensors?
- Does the supplier provide the SDS and technical data sheet?
- Does the product have the correct CLP label?
- Does the disinfectant have the required status and intended purpose?
- Is the cost compared as the cost of the working solution, rather than just the price per litre of concentrate?
- Does the product cause excessive foaming, wastewater problems or secondary deposits?
13. Practical instructions for the facility
A company using CIP should have a short, clear set of instructions for operators. The instructions should specify: who starts the program, when CIP is performed, which chemicals are connected, what the process parameters are, how to check that the cycle was performed correctly, what to do in the event of an alarm and when to report a deviation.
Minimum elements of CIP instructions
- name of the installation or line the program covers,
- sequence of stages: rinse, alkali, rinse, acid, rinse, disinfection,
- name of the chemical and its working concentration,
- temperature and time for each stage,
- required flow or pressure,
- rinse end criterion, e.g. conductivity or pH,
- personal protective equipment for the operator,
- prohibitions on mixing chemicals and rules for connecting containers,
- method for recording the cycle and accepting the result,
- procedure for an unsuccessful cycle or alarm.
14. Conclusions and APOLA Professional Chemicals recommendation
CIP is one of the most important tools for maintaining hygiene in closed installations, but its effectiveness depends on the entire process. It is not enough to buy a strong chemical. The product must be selected to suit the soiling, installation materials, water quality, temperature, flow and required final cleanliness.
For most facilities, a practical CIP system should include at least: a pre-rinse stage, alkaline washing, rinsing, acid washing, final rinsing and - if required by the process - a disinfection or sanitisation stage. Each of these stages should have specified parameters and a method of control.
We recommend that before implementing or changing CIP chemicals, an analysis be prepared: type of soiling, installation materials, current program parameters, microbiological results, water quality, washing frequency, problems with deposits and working solution costs. This approach allows chemicals to be selected professionally, rather than solely on the basis of the price per litre of concentrate.
FAQ - most common questions
Does CIP mean disinfection?
No. CIP means washing in place, without dismantling the installation. Disinfection or sanitisation may be one of the process stages, but it does not replace washing. Soiling must be removed first, and only then should the disinfection or sanitisation stage be carried out, if required.
Can regular foam chemicals be used for CIP?
Usually no. CIP most commonly requires low-foaming chemicals, because foam can disrupt the operation of pumps, sensors, flow meters and spray balls. The product should be intended for use in a closed circuit.
Is alkaline washing sufficient?
It depends on the soiling. Alkaline washing mainly removes fats, proteins and organic soiling. If mineral deposits, milk stone or calcium deposits form in the installation, an acid stage may also be required.
Can acidic and alkaline chemicals be mixed?
This should not be done. Stages should be separated by rinsing, unless the manufacturer and technological procedure state otherwise. Mixing chemicals can cause reactions, heat generation, foaming, loss of effectiveness and risk to the operator.
How can you check if CIP was effective?
Effectiveness can be assessed by controlling process parameters, conductivity, pH, temperature, flow, microbiological tests, ATP, rinse analysis, inspection and periodic validation. The method depends on the industry and product risk.
Do stronger chemicals solve CIP problems?
Not always. The problem may stem from too low flow, dead zones, poorly selected nozzles, mineral deposits, incorrect temperature, poor water quality or the absence of an acid stage. Before increasing the concentration, it is worth analysing the entire process.
Sources and factual basis
- European Hygienic Engineering & Design Group, EHEDG Guidelines Catalogue - guidelines on hygienic design, cleaning, validation and installation in the food industry.
- EHEDG, “Cleaning Validation in the Food Industry – General Principles” - information on cleaning validation, monitoring and verification in the food production environment.
- Regulation (EC) No 852/2004 on the hygiene of foodstuffs - hygiene requirements for food business operators.
- ECHA, Safety Data Sheets - information on SDS and hazard communication in the supply chain.
- Regulation (EC) No 1272/2008 - CLP - classification, labelling and packaging of substances and mixtures.
- Regulation (EC) No 1907/2006 - REACH - basic EU legislation on chemicals and safety data sheets.
- Regulation (EU) No 528/2012 on biocidal products - requirements for the placing on the market and use of biocidal products.
- ECHA, Biocidal Product Types - classification of biocidal product types under the BPR.
- Regulation (EU) 2026/405 on detergents and surfactants - requirements for detergents and surfactants.
This article is for informational purposes only and does not replace process validation, the safety data sheet of a specific product, the technical data sheet, the equipment manufacturer's instructions, occupational risk assessment or procedures applicable at a given facility. When designing and using CIP, always take into account the specific equipment, soils, materials, water quality and industry requirements.